Seite 1 - P/N IGUP-AB-0904

/ChinoABUPRIGHT MEAT DISPLAY CASEREV. 0904Installation& OperationManualABUPRIGHT MEAT DISPLAY CASEP/N IGUP-AB-0904INSTALLATION & OPERATION GUI

Seite 2 - Code having jurisdiction

IGUP-AB-090410MODELS “SCH & SCHMS” - EMITTER NOZZLE CLEANING INSTRUCTIONSIf the nozzle appears plugged or seems to sputter, it may be that some pa

Seite 3 - Important Information

Rev. 090411Humidity System, Cont’dTROUBLE SHOOTING GUIDEProblem Possible Cause / RemedyCompressor not running • Loss of power to controller.Check 110V

Seite 4 - 28 1/8"

IGUP-AB-090412RefrigerationREFRIGERANT TYPEThe standard refrigerant will be R-22 unless otherwisespecified on the customer order. Check the serial pla

Seite 5 - WITH NSF APPROVED SEALANT

Rev. 090413ElectricalWIRING COLOR CODEColor Description Descripcion DescripcionGROUND TIERRA MASA MASSEANTI-SWEAT ANTICONDENSCION ANTI-SUINTEMENTLIGHT

Seite 6

IGUP-AB-090414User InformationNON-GLARE GLASSThe high optical clarity of this glas is possible due to sepcialcoatings on the glass surface itself. To

Seite 7

Rev. 090415User Information, Cont’d

Seite 8

IGUP-AB-090416MaintenanceELECTRICAL PRECAUTIONSBEFORE SERVICING – Always disconnectelectrical power at the main disconnect whenservicing or replacing

Seite 9 - IN MINUTES

Rev. 090417Electrical SchematicsDate:Project Title:Drawing No.:Drawn By:Assembly: Drawing Title:Date:Hussmann Corporation, Int'l.13770 Ramona Ave

Seite 10 - IGUP-AB-0904

IGUP-AB-090418Date:Project Title:Drawing No.:Drawn By:Assembly: Drawing Title:Date:Hussmann Corporation, Int'l.13770 Ramona Avenue, Chino, CA. 91

Seite 11 - MAJOR SYSTEM COMPONENTS

Rev. 090419Date:Project Title:Drawing No.:Drawn By:Assembly:Drawing Title:Date:Hussmann Corporation, Int'l.13770 Ramona Avenue, Chino, CA. 91710(

Seite 12 - 8", or 1

IGUP-AB-09042/ChinoA publication ofHussmann® Chino13770 Ramona Avenue • Chino, California 91710(909) 628-8942 FAX(909) 590-4910(800) 395-9229Keep this

Seite 13 - CASE MUST BE GROUNDED

IGUP-AB-090420Date:Project Title:Drawing No.:Drawn By:Assembly: Drawing Title:Date:Hussmann Corporation, Int'l.13770 Ramona Avenue, Chino, CA. 91

Seite 14 - User Information

Rev. 090421Date:Project Title:Drawing No.:Drawn By:Assembly: Drawing Title:Date:Hussmann Corporation, Int'l.13770 Ramona Avenue, Chino, CA. 91710

Seite 15 - User Information, Cont’d

IGUP-AB-090422Appendix A. – Temperature GuidelinesRefrigeratedThe refrigerators should be operated according to themanufacturer’s published engineerin

Seite 16 - 115 V. ELECTRICAL CIRCUITS

Rev. 090423data which, coupled with other observations, may beused to determined whether a display refrigerator isworking as intended:a) INSTRUMENT –

Seite 17 - Electrical Schematics

IGUP-AB-090424f) Minimize the transfer time of perishables fromstorage to display.g) Keep meat under refrigeration in meat cutting andprocessing area

Seite 18

Rev. 090425

Seite 19 - Gravity Coil

IGUP-AB-090426Limited WarrantyThis warranty is made to the original user at the original installation site and is not transferable.Hussmann merchandis

Seite 20 - Humidifier Air Pump

Rev. 090427The MODEL NAME and SERIAL NUMBER is required in order to provide youwith the correct parts and information for your particular unit.They ca

Seite 21 - Rev. 0904

Rev. 09043The AB Meat merchandisers are easy to work, attractivemerchandising display cases capable of maintaining superbproduct quality, with the ins

Seite 22

IGUP-AB-09044Cut & Plan ViewsWIRE RACKBALLASTHUMIDITY SYSTEM28 1/8"85 5/16"49"28"WATER SUPPLYTO HAND VALVEBALLAST & TERMIN

Seite 23 - Appendices, Cont’d

Rev. 09045PER NSF INSTALLATION REQUIREMENT SEAL AROUND CASE TO BASE PERIMETER WITH NSF APPROVED SEALANTNSF Installation Requirement

Seite 24

IGUP-AB-09046PlumbingWASTE OUTLET AND P-TRAPThe waste outlet is located off the center of the case onone side allowing drip piping to be run lengthwis

Seite 25

Rev. 09047Fractal Humidity SystemGENERAL INFORMATIONThe Service Case Humidification system is an automaticmoisture maintenance system designed to rais

Seite 26

IGUP-AB-09048

Seite 27 - Service Record

Rev. 09049Recommended operation times: You should adjust yourhumidification time for your stores needs~ This is becauseeach service case and floral di